LABORATORY INSTRUMENTS/EQUIPMENTS

SKSES-HOT AIR OVEN.HOT AIR OVEN -200°C-Inner-304grade-Outer-MS Powder coated
Chamber Design Double walled
Inner Chamber Inner chamber made of stainless steel 304 Grade
Insulation Insulation between inner and outer chamber is filled with high grade glasswool with a gap of 75mm thickness, to withstand maximum Temperature200°C
Air Circulation Fan Motor The motorized forced air circulation is provided at the back to maintain uniform temperature inside the chamber
Heaters Air Heaters are made of high grade Kanthal wires of suitable wattage.
Gasket An asbestos rope or Neoprene rubber (optional) gasket is provided for the door to avoid air leakage and temperature loss from Instrument.
Trays Three perforated removable stainless steel trays at the fixed distance.
Temperature Range 5 °C above ambient to 200°C.
Temperature Controller Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting with Cr Al thermocouple and Timer control (optional).
Temperature Resolution 0.1°C
Temperature Accuracy ± 1°C.
Temperature Accuracy ± 2°C.
Temperature Uniformity ± 3°C.
Power Supply 230 Volts Single Phase 50Hz, AC supply.td>
HOT AIR OVEN -200°C-Inner-304grade-Outer-MS Powder coated.
SL.NO Liters.Cap Model No Inner chamber size[WXDXH]cm Outer chambersize[WXDXH]cm 21+X-41+X-40+X Power in[watts] No.of Trays
1 5 SKSES-7-200 17.5x17.5 38.5 x 60 x 57.5 750 2
2 42 SKSES -14-200 35X 35 X 35 56 x 76 x 75 1200 2
3 90 SKSES -18-200 45X 45 X 45 66 x 86 x 84 1500 3
4 120 SKSES -18/24-200 45X 45 X 60 66 x 86 x 100 1750 3
5 210 SKSES -24-200 60 x 60 x 60 81 x 101 x 100 2000 3
6 320 SKSES -24/36-200 60 x 60 x 90 81 x 102.5 x 130 3000 3

SKSES-BACTERIOLOGICAL INCUBATOR Bacteriological Incubator + 5 °C above ambient to 65°C.-Inner-304grade-Outer-MS Powder coated

Chamber Design Double walled
Inner Chamber Inner chamber made of stainless steel 304 Grade
Outer Chamber Outer chamber made of mild steel and finished with powder coated.
Insulation Insulation between inner and outer chamber is filled with high grade glass
Air Circulation Fan Motor The motorized forced air circulation is provided at the back to maintain uniform temperature inside the chamber
Heaters Tubular air heater are made of high grade Kanthal wires of suitable wattage.
Inner Glass Door Inner full- length glass door is provided to view the samples without disturbing the temperature
Gasket Rubber gasket and latch is provided for the door is provided for the door to avoid air leakage and temperature loss from Instrument.
Trays Three perforated removable stainless steel trays at the fixed distance.
Temperature Range 5 °C above ambient to 65°C
Temperature Controller Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting with PT100 sensor and Timer control (optional).
Temperature Resolution ± 2°C.
Temperature Uniformity 0.1°C.
Temperature Accuracy ± 1°C.
Power Supply 230 Volts Single Phase 50Hz, AC supply.
Bacteriological Incubator + 5 °C above ambient to 65°C.-Inner-304grade-Outer-MS Powder coated
SL.NO Liters.Cap Model No Inner chamber size[WXDXH]cm Power in[watts]
1 42 SKSES-BI-14 35X 35 X 35 400
2 42 SKSES -BI-18 45 X 45X 45 500
3 120 SKSES- BI-18/24 45X 45 X 60 600
4 210 SKSES -BI-24 60X 60 X 60 750
5 320 SKSES- BI-24/36 60X 60 X 90 1000
B O D INCUBATOR+10°C to 65°C-Inner-SS-304grade-Outer-MS Powder coated.
Chamber Design Double walled
Inner Chamber Inner chamber made of stainless steel 304 Grade
Outer Chamber Outer chamber made of mild steel and finished with powder coated.
Insulation Insulation between inner and outer chamber is filled with high grade glass wool with a gap of 65mm thickness, to withstand maximum Temperature 60°C
Conditioning system Air Circulation Fan Motor The triple walled back of the instrument is provided with air circulation fans. The chamber is equipped with a vertical recalculating conditioning stream of air sucking from the top of the inner chamber and allows passing through Theback sideof theinner chamber rductandcarrying heating/cooling/humidity which enters from the bottom of the chamber this process continuous to maintain uniformity throughout the chamber.
Cooling Tubular air heater are made of high grade Kanthal wires of suitable wattage.
Inner Glass Door An energy efficient cooling unit is installed in our instrument hermetically sealed compressors. These compressors are the heavy duty industrial type noise free, vibration free and air cooled Compressors start in sequence to protect the unit from overloading. We use CFC free environmentally friendly refrigerant and compressors of Kirloskar/Tecumseh make, conforming to latest international standards and guidelines
Inner Glass Door Inner full- length glass door is provided to view the samples without disturbing the temperature
Outer Door Inner stainless steel and Outer made of Mild steel finished with powder coated
Gasket Rubber gasket and latch is provided for the door is provided for the door to avoid air leakage and temperature loss from Instrument.
Trays Three perforated removable stainless steel trays at the fixed distance.
Temperature Range 10°C to 60°C
Temperature Controller Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting with PT-100 Sensor and Timer control (optional).
Temperature Resolution 0.1°C
Temperature Accuracy ± 2°C
Temperature Uniformity ± 3°C.
BOD Incubator +10°C to 65°C-Inner-SS-304grade-Outer-MS Powder coated.
SL.NO Liters.Cap Model No Inner chamber size[WXDXH]cm Outer chamber size[WXDXH]cm21+X-41+X-40+X Power in[watts]
1 90/3 SKSES-BOD-3 43x 42x 50 54x84x90 750
2 112/4 SKSES-BOD-4 50x 45x 50 63x94x98 1000
3 165/6 SKSES-BOD-6 50x 45x 75 64x90x150 1500
4 285/10 SKSES-BOD-10 58X55X90 73x102x166 2000
5 340/12 SKSES-BOD-12 60x 55x 105 74x103x183 3000
SKSES-Muffle Furnace -1000°C-Outer-MS Powder coated
Chamber Design
Double walled
Inner Chamber Inner muffle wound on kanthal A1 heating elements and embedded with high quality ceramic cement to avoid heat loss
Outer Chamber Outer chamber made of mild steel and finished with powder coated.
Insulation Insulation In between muffle and outer walls insulated with high quality light weight ceramic fiber.
Heaters Air Heaters are made of high grade Kanthal wires of suitable wattage.
Gasket An asbestos rope gasket is provided for the door to avoid air leakage and temperature loss from Instrument.
Temperature Range 5 °C above ambient to 1000°C.
Temperature Controller Microprocessor based PID temperature controller with dual display (Process value and set value), low and high limit setting with Thermocouple CRAL ‘K’ type timer control/optional
Temperature Resolution 0.1°C
Temperature Accuracy ± 3°C.
Temperature Uniformity ± 5°C.
Power Supply 230 Volts Single Phase 50Hz, AC supply
Power Supply 440 Volts Three Phase 50Hz, AC supply.
Muffle Furnace -1000°C-Outer-MS Powder coated
SL.NO Model No Inner chamber size [ WXDXH] cm Outer chamber size [ WXDXH] cm (include panel board & door) 21+X-41+X-40+X Power in Kilo Watts
1 SKSES-MF-494-1000 100x225x100 420x520x650 2
2 SKSES-MF-5105-1000 125x250x125 2.5
3 SKSES-MF-6126-1000 150x300x150 460x650x720 3
4 SKSES-MF-8128-1000 200x300x200 500x650x760 4.5
5 SKSES-MF-9189-1000 225x450x225 530x800x800 7.5 to 9

VACUUM OVEN -200°C-Inner-304grade-Outer-MS Powder coated
Chamber Design
Double walled
Inner Chamber Inner chamber made of stainless steel 304 Grade
Outer Chamber Outer chamber made of mild steel and finished with powder coated.
Insulation Insulation between inner and outer chamber is filled with high grade glass wool with a gap of 65mm thickness
Heaters Memmert type Air Heaters are made of high grade Kanthal wires of suitable wattage, wound on the all around the Chamber.
Gasket Silicon rubber gaskets with effective door locking system for 100% sealing to hold vacuum effectively
Door Glass Window The door has viewing tough glass window with leak proof sealed.
Accessories Fitted It has vacuum gauge, vacuum release valve and vacuum inlet valve
Trays Two perforated removable stainless steel trays at the fixed distance.
Vacuum attainable Vacuum attainable up to 670mm/Hg.
Temperature Range 5 °C above ambient to 200°C.td>
Temperature Controller Microprocessor based PID controller with dual display (Process value and set value), low and high limit setting and Cr Al thermocouple.
TemperatureResolution 0.1°C
TemperatureAccuracy ± 2°C
Temperature Uniformity ± 8°C.
Power Supply 230 Volts Single Phase 50Hz, AC supply.